With safety in mind, the czone system features a manual bypass. By changing the position of the fitted blade fuse on any of the czone output interface oi, motor output interface moi or combination output interface coi modules, the individual circuit can be taken in or out of the czone system. Every czone device on a network requires a unique dipswitch to operate correctly, and the touch 5 has a virtual dipswitch. Czone has a broad network of technical dealers and distributors to support the installation and servicing of czone systems across the globe. With manual fuse overide, quickblow digital fusing, alarms and trigger function logic, youll be safer on a czone smart boat. Note that all the labeling on the show demo below is for one specific boat configuration. Installation builders and installers recognize an immediate benefit with. Browse product images organized by part number to easily find and download high definition jpg files for every product shown on the ancor website. The output interface oi provides an intelligent replacement for traditional circuit breaker and fuse panels.
Czone combination output interface coi quality marine. Czone coi user and installation manual pdf download manualslib. Combination output interface 24 pages recording equipment czone meter interface quick manual. Combination output interface 24 pages recording equipment czone network bridge interface quick manual. View and download czone coi user and installation manual online. Czone app quick start guide czone app quick start guide spanish wireless interface installation manual wireless interface installation manual spanish wireless interface setup instructions wireless interface setup instructions spanish 701mdcz czone configuration guide. Turn on the circuit breaker or switch supplying power to the touch 5. Czone combination output interface coi without connectors. Czone offers builtin redundancy from the digital control and monitoring of system circuits. The czone masterbus bridge interface physically connects the masterbus and czone networks together, enabling the two networks to communicate and act as one. Description part number czone control 1 interface 80911012200 it is obligatory that every person who works on or with the control 1 is completely familiar with the contents of this manual, and that heshe carefully follows the instructions contained herein. The coi digital switch breakout dsb is the interface between the combination output interface coi and up to six czone digital switches push button or rocker. Czone 5 products dan fender 80 products deckmate 19 products dhr 240 products dtorque.
Czone control 1 interface enerdrive independent power solutions. This offers a compact and intelligent replacement for traditional dc fuse boxes and circuit breaker panels. Czone offers the industry leading solution for complete recreational vehicle switching for your smart vehicle. Czone control 1 interface the control 1 interface combines multiple input and output devices into one module. The czone system, designed for 932 v systems, features builtin timers, dimmers including support for halogen lighting, alarms, voltage reducers and load shedding. Dc circuit control and monitoring modules to interface the czone network with traditional mechanical switches and external sensors and meters. Czone meter interface quick manual pdf download manualslib. The czone combination output interface coi banks, each individually labelled, are the heart of the control system with a manual fuse override. Czone oi installation manual czone coi data sheet czone 2.
I installed one of these czone coi systems in my boat. Czone combination output interface coi asap marine. An product introduction of the czone combination output interface coi. Czone control 1 interface dc interfaces mastervolt. En czone coi combination output interface table of contents general information use of this manual guarantee specifications quality validity of this manual liability changes to the combined output interface safety and installation precautions warnings and symbols use for intended purpose. It also provides a sophisticated solution via the automation of complex electrical systems. Czone how to update a config file on a czone system via the coi. The czone splashscreen will appear for about 10 seconds then the text starting. A czone touchscreen is used to operate the system centrally, and as the abyc and ce safety authorities require every circuit to have both a fuse and a bypass, this is provided within the coi.
The czone system decentralises the dc power distribution system, locates circuit control and protection modules closer to loads to shorten cable runs and reduce the size of conductors, significantly decreasing the cost and weight of the electrical wiring harness. The combination output interface coi combines multiple input and output. Related manuals for czone coi recording equipment czone network bridge interface quick manual 2 pages mastervolt czone network bridge interface nbi quick manual. Larger recreational vehicles host complex onboard electrical systems to provide the user with functionality from broad integration for control and monitoring of multiple vehicle systems, to automation of key functions such as power management and storage, and to. The coi digital switch breakout dsb is the interface between the combination output interface coi and up to six czone digital switches. Description part number czone coi cw connectors 80911011900 czone coi no connectors 80911012000 it is obligatory that every person who works on or with the coi is completely familiar with the contents of this manual, and that heshe carefully follows the instructions contained herein. Czone coi user and installation manual pdf download. Dc output interfaces provide an intelligent replacement for traditional circuit breaker and fuse panels. Download czone coi user and installation manual manualslib. Bep czone output interface oi intelligent replacement for. The control 1 combines multiple input and output devices in to a single module, minimizing installation, interconnections and footprint. The coi digital switch breakout dsb is the interface between the coi and up to 6 czone digital switches push button or rocker.
Each atc fuse can be simply withdrawn to isolate a circuit, and pushed into a different position to create a bypass. Czone output interface oi enerdrive independent power. Description part number czone touch 7 80911020000 liability power products can accept no liability for. The combination output interface coi combines multiple input and output devices in to one module, providing a. Digital control and monitoring systems just became more cost effective and easier to install with the czone coi. Refer to the czone configuration tool manual for this process. Czone network bridge interface quick manual pdf download. Nov 30, 2015 the coi will pack the capabilities of several existing czone modules into one less expensive box that can conceivably control all the power needs and many of the sensor needs of a modest vessel. Combination output interface with connectors czone mastervolt. Other features include high power pump channels to allow manual control, plus. The combination output interface coi combines multiple input and output devices into one module. Edwin runs us through, step by step how to update a configuration file on a czone system via the coi. The control 1 incorporates many of the core features and benefits of the fully featured combination output interface coi, but has been reengineered to offer improved costperchannel value.
The system replaces complex wiring with a single data wire. This provides seamless control and monitoring of devices from either masterbus displays, czone displays or integrated products. Czone control and monitoring simplifies installation of electrical systems through the replacement of complicated and often cumbersome traditional wiring. The digital switches include dimmable led backlighting, systems on, fault codes and a plug and play harness simplifying installation. Monitoring and control the czone touch screen offers a yachts electrical status at a glance, and can be seen from any mode. Recording equipment czone coi user and installation manual. Online catalogs marinco catalog marinco n85w12545 westbrook crossing menomonee falls, wi. The coi is essentially a complete czone system in a single, rugged housing, making it a cost effective solution where space and budgets are limited. Czone masterbus bridge interface 80911007200 czone. This minimizes time and effort during installation by reducing connections between multiple modules and the footprint required.